Alarm Logs

Alarm Log Message Format

2022-07-18T21:03:16+0000 alarmLog, applianceName=SDWAN-Controller2, tenantName=Tenant1, 
alarmType=sdwan-datapath-down, alarmKey=SDWAN-Controller2|WAN2|SDWAN-Branch1|WAN1|fc_nc, 
generateTime=1658178227, applianceId=1, vsnId=0, tenantId=2, 
alarmCause=connectionEstablishmentError, alarmClearable=yes, alarmClass=cleared, 
alarmKind=symptom, alarmEventType=communicationsAlarm, alarmSeverity=cleared, 
alarmOwner=tenant, alarmSeqNo=1198, 
alarmText="Datapath from SDWAN-Controller2/WAN2 to SDWAN-Branch1/WAN1 for fwdClass fc_nc is up ", 
alarmKeyExt=SDWAN-Controller2, serialNum=N/A

Alarm Log Message Fields

Field Description
alarmLog Alarms generated by VOS devices when the alarm-log log type is configured.
applianceName

Name of the VOS device. This is the name displayed in the output of the show system identification branch CLI command.

tenantName Name of the organization (tenant).
alarmType Type of alarm. For more information, see Supported Alarm Types in Configure VOS Device Alarms.
alarmKey String generated by the VOS device that uniquely identifies the alarm.
generateTime Time when the alarm occurred, in UNIX epoch time format.
applianceId VOS device identifier. This field is not used.
vsnId Identifier of the virtual service node, or virtual machine (VM).
tenantId Tenant identifier. This value is allocated internally by the VOS device.
alarmCause Cause of the alarm.
alarmClearable Whether the alarm has an associated clear notification.
alarmClass

Alarm class:

  • Changed
  • Cleared
  • New
alarmKind

Type of alarm:

  • Root cause
  • Symptom
  • Unknown
alarmEventType Alarm event type. Examples are communicationsAlarm and qualityOfServiceAlarm.
alarmSeverity

Severity of the alarm. For more information, see Alarm Severity Levels in Configure VOS Device Alarms.

  • Critical
  • Intermediate
  • Major
  • Minor
  • Warning
alarmOwner

Alarm owner:

  • Customer tenant
  • Provider tenant
alarmSeqNo Unique alarm sequence number generated for a tenant and VOS device.
alarmText Text description of the alarm.
alarmKeyExt

Additional information about the alarm.

serialNum Serial number of the VOS device.

 

Supported Software Information

Releases prior to 20.2.3 support all content in this article.