SD-WAN Alarms
For supported software information, click here.
sdwan-branch-disconnect
Description | Generated on a Controller node when the node lost connectivity on all overlay paths. |
Cause |
|
Related Commands
- Issue the show system uptime CLI command on the device to check branch reboot.
admin@vCPE101-cli> show system uptime Current time : Mon Sep 18 23:43:29 2017 System start time : Wed Sep 13 17:59:26 2017 Service uptime : 5 days, 5 hours, 44 minutes, 3 seconds
- Issue the show coredumps CLI command on the device to check for software crash.
admin@vCPE101-cli> show coredumps total 636K -rw-rw-r-x 1 root root 634K Jul 5 18:25 core.versa-vsmd.1536.versa-flexvnf.1499304350.gz
- Issue the last shell command on the device.
admin@vCPE101:~$ last admin pts/1 10.42.107.254 Mon Sep 18 22:42 still logged in admin pts/1 10.42.107.254 Thu Sep 14 00:08 - 02:20 (02:12) admin pts/1 10.42.107.254 Wed Sep 13 21:39 - 21:40 (00:00) admin pts/1 10.42.20.63 Wed Sep 13 17:54 - 21:15 (03:20) reboot system boot 3.16.0-77-generi Wed Sep 13 17:28 - 23:45 (5+06:16) admin pts/3 10.42.20.52 Thu Sep 7 18:58 - 18:58 (00:00) admin pts/3 10.42.20.52 Thu Sep 7 18:58 - 18:58 (00:00) admin pts/3 10.42.20.52 Thu Sep 7 18:58 - 18:58 (00:00) admin ttyl Thu Sep 7 15:52 - crash (6+01:36) reboot system boot 3.16.0-77-generi Thu Sep 7 15:52 - 23:45 (11+07:53)
- Issue the show alarms | grep InterfaceDown CLI command to view related alarms.
admin@vCPE101-cli> show alarms | grep InterfaceDown system interfaceDown 2017-08-25T17:06:13-0 Provider1: Interface vni-0/0 is down (n/a) system interfaceDown 2017-08-25T17:06:13-0 Customer1: Interface vni-0/0 is down (n/a) system interfaceDown 2017-09-06T18:29:28-0 Customer1: Interface vni-0/2.0 is down (n/a) system interfaceDown 2017-09-06T18:29:28-0 Provider: Interface vni-0/2 is down (n/a) sdwan-datapath-down
sdwan-datapath-down
Description | Generated on a branch/hub or controller device when the device dropped connectivity on an overlay path for a specific traffic class. |
Cause |
|
Action |
|
Related Commands
- Issue the show orgs org-services customer-name class-of-service interfaces brief to view the interface details of the class of service.
admin@Branch1-cli> show orgs org-services Customer1 class-of-service interfaces brief TX TX TX BYTES QUEUE NAME TX PACKETS PPS DROPPED TX BYTES TX BPS DROPPED LEN ------------------------------------------------------------------------------------------ vni-0/0 1310714652 8118 528060889 170523706647 8445072 68653181638 0 vni-0/1 1775447 14 0 500764808 10592 0 0
- Issue the show orgs org-services customer-name class-of-service interfaces detail CLI command to view the complete interface details of the class of service.
admin@Branch1-cli> show orgs org-services Customer1 class-of-service interfaces detail Interface: vni-0/0 Traffic Stats: TX Pockets : 1310925543 TX PPS : 6740 TX Pockets Dropped : 528248928 TX Bytes : 170551126910 TX bps : 7006120 TX Bytes Dropped : 68677641264 Port Stats : Traffic Class TX Pkts TX Dropped TX Bytes Bytes Dropped tc0 network-control 537069 0 101380702 0 tcl expedited-fwd 273302 0 53059188 0 tc2 assured-fwd 273282 0 53044312 0 tc3 best-effort 1309841890 528248928 170343642688 68677641264 Pipe Stat: Pipe ID : 0 Users : [Default] Traffic Class TX Pkts TX Dropped TX Bytes Bytes Dropped tc0 network-control 537069 0 101380702 0 tcl expedited-fwd 273302 0 53059188 0 tc2 assured-fwd 273282 0 53044132 0 tc3 best-effort 1303841890 528248928 170343642688 68677641264
- Issue the show orgs org organization-name sd-wan sla-monitor metrics last CLI command to view the SD-WAN's SLA monitor metrics. Note that SLA metrics are exported from CPE devices only if the path is in the active state. If the path is in the suspend or suspend-retry state, no logs are sent because these paths are not actively carrying traffic.
admin@KVM-Branch1-cli> show orgs org Org1 sd-wan sla-monitor metrics last LOCAL REMOTE REMOTE WAN WAN TWO FWD REV PDU FWD REV PATH FWD LOCAL WAN WAN LINK LINK WAY DELAY DELAY LOSS LOSS LOSS FWD REV SITE NAME HANDLE CLASS LINK LINK ID ID DELAY VAR VAR RATIO RATIO RATIO LOSS LOSS -------------------------------------------------------------------------------------------------------------------------------------------------- KVM-Branch2 6689024 fc_nc WAN1 WAN1 1 1 0 1 1 0 0 0 0 0 6689280 fc_nc WAN1 WAN2 1 2 0 1 1 0 0 0 0 0 6693120 fc_nc WAN2 WAN1 2 1 0 1 1 0 0 0 0 0 6693376 fc_nc WAN2 WAN2 2 2 0 1 1 0 0 0 0 0 6697728 fc_nc WAN3 WAN3 3 3 0 2 1 0 0 0 0 0 6706432 fc_nc WAN1-IPv6 WAN1-v6 5 5 0 2 1 0 0 0 0 0 6706688 fc_nc WAN1-IPv6 WAN2-v6 5 6 0 1 1 0 0 0 0 0 6710528 fc_nc WAN2-IPv6 WAN1-v6 6 5 0 0 0 100 0 0 0 0 6710784 fc_nc WAN2-IPv6 WAN2-v6 6 6 0 0 0 100 0 0 0 0 6715136 fc_nc WAN3-IPv6 WAN3-v6 7 7 0 1 1 0 0 0 0 0 KVM-Branch3 6754560 fc_nc WAN1 WAN1 1 1 0 2 2 0 0 0 0 0 6754816 fc_nc WAN1 WAN2 1 2 0 2 2 0 0 0 0 0 6758656 fc_nc WAN2 WAN1 2 1 0 2 2 0 0 0 0 0 6758912 fc_nc WAN2 WAN2 2 2 0 2 2 0 0 0 0 0 6763264 fc_nc WAN3 WAN3 3 3 0 2 2 0 0 0 0 0 SDWAN-Controller-ESXi 78080 fc_nc WAN3 WAN3 3 1 0 0 0 0 0 0 0 0 95488 fc_nc WAN3-IPv6 WAN3-v6 7 5 0 0 0 0 0 0 0 0 sdwan-datapath-sla-not-met
sdwan-datapath-sla-not-met
Description | Generated on the branch/hub per SD-WAN rule when the SLA metrics did not comply with configured value for the rule. |
Cause | If CoS is enabled and if there are drops for a forwarding class. |
Action |
|
Related Commands
- Issue the show orgs org-services customer-name sd-wan policies p1 rules path-state brief CLI command to view the SD-WANs policies and rule path details.
adnin@Branch1-cli> show orgs org-services Customer1 sd-wan policies p1 rules path -state brief REMOTE FORWARDING SLA LOCAL REMOTE FORWARDING NAME BRANCH PROFILE PROFILE CIRCUIT CIRCUIT CLASS PRIORITY --------------------------------------------------------------------------------------------------------------------------------- RULE1 Branch2 fpI sp1 BroadBand BroadBand fc_be SLA Violated MPLS MPLS fc_be 1 Branch3 fp1 sp1 BroadBand BroadBand fc_be SLA Violated MPLS MPLS fc_be 1 Controller1 fp1 sp1 BroadBand C1 -Broadband fc_be SLA Violated MPLS C1-MPLS fc_be Default Controller2 fp1 sp1 BroadBand C2 -Broadband fc_be Down MPLS C2-MPLS fc_be Default
admin@KVM-Branch1-cli> show orgs org Org1 sd-wan sla-monitor metrics last LOCAL REMOTE REMOTE WAN WAN TWO FWD REV PDU FWD REV PATH FWD LOCAL WAN WAN LINK LINK WAY DELAY DELAY LOSS LOSS LOSS FWD REV SITE NAME HANDLE CLASS LINK LINK ID ID DELAY VAR VAR RATIO RATIO RATIO LOSS LOSS ------------------------------------------------------------------------------------------------------------------------------- KVM-Branch2 6689024 fc_nc WAN1 WAN1 1 1 0 1 1 0 0 0 0 0 6689280 fc_nc WAN1 WAN2 1 2 0 1 1 0 0 0 0 0 6693120 fc_nc WAN2 WAN1 2 1 0 1 1 0 0 0 0 0 6693376 fc_nc WAN2 WAN2 2 2 0 1 1 0 0 0 0 0 6697728 fc_nc WAN3 WAN3 3 3 0 2 1 0 0 0 0 0 6706432 fc_nc WAN1-IPv6 WAN1-v6 5 5 0 2 1 0 0 0 0 0 6706688 fc_nc WAN1-IPv6 WAN2-v6 5 6 0 1 1 0 0 0 0 0 6710528 fc_nc WAN2-IPv6 WAN1-v6 6 5 0 0 0 100 0 0 0 0 6710784 fc_nc WAN2-IPv6 WAN2-v6 6 6 0 0 0 100 0 0 0 0 6715136 fc_nc WAN3-IPv6 WAN3-v6 7 7 0 1 1 0 0 0 0 0 KVM-Branch3 6754560 fc_nc WAN1 WAN1 1 1 0 2 2 0 0 0 0 0 6754816 fc_nc WAN1 WAN2 1 2 0 2 2 0 0 0 0 0 6758656 fc_nc WAN2 WAN1 2 1 0 2 2 0 0 0 0 0 6758912 fc_nc WAN2 WAN2 2 2 0 2 2 0 0 0 0 0 6763264 fc_nc WAN3 WAN3 3 3 0 2 2 0 0 0 0 0 SDWAN-Controller-ESXi 78080 fc_nc WAN3 WAN3 3 1 0 0 0 0 0 0 0 0 95488 fc_nc WAN3-IPv6 WAN3-v6 7 5 0 0 0 0 0 0 0 0
Supported Software Information
Releases 20.2 and later support all content described in this article.
Additional Information
Configure SLA Profiles for SD-WAN Traffic Steering
Configure VOS Device Alarms