AMQP Event Notifications
For supported software information, click here.
When you enable object notification in Director and when an event occurs on a Director node or a Versa Operating SystemTM (VOSTM) device, Versa Director publishes event AMQP notifications.
An event notification is called by a routing key, and it has the following format:
[Severity].[Event-Type].[Event-Entity].[Organization].[User]
The following table explains the components of the routing key.
Field | Description |
---|---|
Severity |
How severe the event is:
|
Event Type | http://director-ip-address:port/api/config/alarms/alarm-model/alarm-type |
Event Entity | Device identifier. |
Organization | Organization identifier. If there is no organization, the default is System. |
User | Name of the user. For system-level actions, the user is System. |
Note that for Releases 20.2 and later, all ZTP AMQP event notification keys use hyphens instead of underscores. For example, ztp_staging_start changes to ztp-staging-start.
Appliance CPU Threshold
Routing Key
Critical.versa-director-evt:appliance-cpu-usage-exceeded-hard-limit.7bc14324-f21c-4841-b8df-49400e7afd4a.System.System
AMQP Notification
{ "message_id ": 62, "event_type ": "versa - director - evt: appliance - cpu - usage - exceeded - hard - limit ", "event_entity ": "7 bc14324 - f21c - 4841 - b8df - 49400e7 afd4a ", "severity ": "Critical ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: appliance - cpu - usage - exceeded - hard - limit ", "eventText ": "CPU usage on appliance osapp3,slot - id: 0(VM name: osapp3 - VCSN - VM) exceeded hard limit.Threshold value: [CPU usage: 90] current value[94]" }, "event_time ": "2015 - 03 - 06 T17: 38: 40.263000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": " / versa - nms: nms / provider / appliances / appliance[uuid = '7bc14324-f21c-4841-b8df-49400e7afd4a']" }
Appliance Creation
Routing Key
Indeterminate.versa-evt:create-object.Branch-COLT.COLT.System
AMQP Notification
{ "message_id": 7348, "event_type": "versa-evt:create-object", "event_entity": "Branch-COLT", "severity": "Indeterminate", "organization": "COLT,Versa", "user": "System", "payload": { "appliance-name": "Branch-COLT", "eventText": "create-object status:SUCCESS", "uuid": "11520295-5c98-4e2c-a767-28f8e4d28749", "serialNum": "SR207" }, "event_time": "2019-03-19T08:57:23.213000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "Branch-COLT-create-object" }
Appliance Deletion
Routing Key
Indeterminate.versa-director-evt:delete-appliance.JustOneMore.System.System
AMQP Notification
{ "message_id": 584, "event_type": "versa-director-evt:delete-appliance", "event_entity": "JustOneMore", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:delete-appliance", "eventText": "status:SUCCESS" }, "event_time": "2016-02-11T09:15:53.680000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[name='JustOneMore']" }
Appliance Down, Not Reachable
Routing Key
Major.versa-director-evt:appliance-ping-state-change.1e99490c-83f6-4fae-8d74-ea64bcd09c87.System.System
AMQP Notification
{ "message_id": 65, "event_type": "versa-director-evt:appliance-ping-state-change", "event_entity": "1e99490c-83f6-4fae-8d74-ea64bcd09c87", "severity": "Major", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:appliance-ping-state-change", "eventText": "Versa Appliance Ranga-App : Ping Status changed from REACHABLE to UNREACHABLE. Additional information[ ]" }, "event_time": "2016-01-13T07:28:05.714000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[uuid= '1e99490c-83f6-4fae-8d74-ea64bcd09c87']" }
Appliance Final Configuration Completed
Routing Key
Indeterminate.versa-evt:appliance-final-configuration-completed.Branch7.System.System
AMQP Notification
{ "message_id": 4, “event_type ":" versa - evt: appliance - final - configuration - completed ", "event_entity": "Branch7", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": " versa-evt:appliance-final-configuration-completed ", "eventText": " appliance-final-configuration-completedstatus:SUCCESS" }, "event_time": " 2017-07-21T00:41:46.085000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "Branch7-appliance-final-configuration-completed" }
Appliance HA Switchover
Routing Key
Indeterminate.versa-evt:ha-state-change.App1.System.System
AMQP Notification
{ "message_id": 120, "event_type": "versa-evt:ha-state-change", "event_entity": "App1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:ha-state-change", "eventText": "HA: VSN: 0 in Inter-Chassis mode, changing role to HA-Active during appliance-switchover" }, "event_time": "2016-01-29T14:49:14.000000-00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/ncs:devices/ncs:device[ncs:name='App1']/config//ha:redundancy" }
Routing Key
Indeterminate.versa-evt:ha-state-change.Ranga-App.System.System
AMQP Notification
{ "message_id": 121, "event_type": "versa-evt:ha-state-change", "event_entity": "App", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:ha-state-change", "eventText": "HA: VSN: 0 in Inter-Chassis mode, changing role to HA-Standby during bootup" }, "event_time": "2016-01-29T14:49:22.000000-00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/ncs:devices/ncs:device[ncs:name='App']/config//ha:redundancy" }
Appliance Memory Threshold
Routing Key
Critical.versa-director-evt:appliance-memory-usage-exceeded-hard-limit.7bc14324-f21c-4841-b8df-49400e7afd4a.System.System
AMQP Notification
{ "message_id ": 62, "event_type ": "versa - director - evt: appliance - memory - usage - exceeded - hard - limit ", "event_entity ": "7 bc14324 - f21c - 4841 - b8df - 49400e7 afd4a ", "severity ": "Critical ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: appliance - memory - usage - exceeded - hard - limit ", "eventText ": "Memory usage on appliance osapp3,slot - id: 0(VM name: osapp3 - VCSN - VM) exceeded hard limit.Threshold value: [Memory usage: 70] current value[78]" }, "event_time ": "2015 - 03 - 06 T17: 38: 40.263000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": " / versa - nms: nms / provider / appliances / appliance[uuid = '7bc14324-f21c-4841-b8df-49400e7afd4a']" }
Appliance Power Status Change from On to Off
Routing Key
Critical.versa-director-evt:appliance-power-state-change.7bc14324-f21c-4841-b8df-49400e7afd4a.System.System
AMQP Notification
{ "message_id ": 34, "event_type ": "versa - director - evt: appliance - power - state - change ", "event_entity ": "7 bc14324 - f21c - 4841 - b8df - 49400e7 afd4a ", "severity ": "Critical ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: appliance - power - state - change ", "eventText ": "osapp3: Appliance Power Status changed from POWERED_ON to POWERED_OFF.Additional information[]" }, "event_time ": "2015 - 03 - 06 T15: 01: 57.125000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": " / versa - nms: nms / provider / appliances / appliance[uuid = '7bc14324-f21c-4841-b8df-49400e7afd4a']" }
Appliance Services Degradation
Routing Key
Critical.versa-director-evt:appliance-services-state-change.7bc14324-f21c-4841-b8df-49400e7afd4a.System.System
AMQP Notification
{ "message_id ": 62, "event_type ": "versa - director - evt: appliance - services - state - change ", "event_entity ": "7 bc14324 - f21c - 4841 - b8df - 49400e7 afd4a ", "severity ": "Critical ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: appliance - services - state - change ", "eventText ": "osapp3: Services Status changed from GOOD to DEGRADED.Additional information[]" }, "event_time ": "2015 - 03 - 06 T17: 38: 40.263000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": " / versa - nms: nms / provider / appliances / appliance[uuid = '7bc14324-f21c-4841-b8df-49400e7afd4a']" }
Appliance Services Down
Routing Key
Critical.versa-director-evt:appliance-services-state-change.7bc14324-f21c-4841-b8df-49400e7afd4a.System.System
AMQP Notification
{ "message_id": 6673, "event_type": "versa-evt:appliance-services-state-changed", "event_entity": "Branch-Pepsi", "severity": "Critical", "organization": "Pepsi-Eng,Versa,Pepsi,Pepsi-Finance", "user": "System", "payload": { "appliance-name": "Branch-Pepsi", "eventText": "appliance-services-state-changed Versa Appliance Branch-Pepsi : Services Status changed from GOOD to UNKNOWN. Additional information[ ]", "uuid": "ac604ca8-9ad3-4398-a566-1c0564ca346e", "serialNum": "SR101" }, "event_time": "2019-03-18T06:36:45.419000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[uuid= 'ac604ca8-9ad3-4398-a566-1c0564ca346e']" }
Appliance Sync State Change
Routing Key
Minor.versa-director-evt:appliance-sync-state-change.1e99490c-83f6-4fae-8d74-ea64bcd09c87.System.System
AMQP Notification
{ "message_id": 6674, "event_type": "versa-evt:appliance-sync-state-changed", "event_entity": "Branch-Pepsi", "severity": "Minor", "organization": "Pepsi-Eng,Versa,Pepsi,Pepsi-Finance", "user": "System", "payload": { "appliance-name": "Branch-Pepsi", "eventText": "appliance-sync-state-changed Versa Appliance Branch-Pepsi : Sync Status changed from IN_SYNC to UNKNOWN. Additional information[ ]", "uuid": "ac604ca8-9ad3-4398-a566-1c0564ca346e", "serialNum": "SR101" }, "event_time": "2019-03-18T06:36:45.419000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[uuid= 'ac604ca8-9ad3-4398-a566-1c0564ca346e']" }
Disable Versa Director HA
Routing Key
Indeterminate.versa-director-evt:ha-disable.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 11, "event_type": "versa-director-evt:ha-disable", "event_entity": "VOAEDEVHA1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-disable", "eventText": "status:STARTED,triggered_by:Administrator," }, "event_time": "2015-03-07T08:05:32.146000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:disable-ha" }
Routing Key
Indeterminate.versa-director-evt:ha-disable.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 12, "event_type": "versa-director-evt:ha-disable", "event_entity": "VOAEDEVHA1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-disable", "eventText": "status:SUCCESS,triggered_by:Administrator," }, "event_time": "2015-03-07T08:05:32.617000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:disable-ha" }
Enable Versa Director HA
Routing Key
Indeterminate.versa-director-evt:ha-enable.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 13, "event_type": "versa-director-evt:ha-enable", "event_entity": "VOAEDEVHA1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-enable", "eventText": "status:STARTED,triggered_by:Administrator," }, "event_time": "2015-03-07T08:10:31.055000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:enable-ha" }
Routing Key
Indeterminate.versa-director-evt:ha-enable.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 17, "event_type": "versa-director-evt:ha-enable", "event_entity": "VOAEDEVHA1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-enable", "eventText": "slave:10.192.27.27,status:SUCCESS,master:10.192.27.26,triggered_by:Administrator," }, "event_time": "2015-03-07T08:10:54.401000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:enable-ha" }
Scale In
Routing Key
Indeterminate.versa-director-evt:scale-in.10March.System.System
AMQP Notification
{ "message_id": 8, "event_type": "versa-director-evt:scale-in", "event_entity": "10March", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:scale-in", "eventText": "cpuUtil:1,iocapacityutil:0,memoryUtil:10,miscloadFactor:1,sng-id:0,capacity:0.0,vcpu:8,vnics:5,vsns:1,status:SUCCESS" }, "event_time": "2015-03-10T14:40:52.356000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[name='10March']" }
Scale Out
Routing Key
Indeterminate.versa-director-evt:scale-out.10March.System.System
AMQP Notification
{ "message_id": 6, "event_type": "versa-director-evt:scale-out", "event_entity": "10March", "severity": "Indeterminate", "organization": "System", "user": "System", "payload ": { "alarm - type ": "versa - director - evt: scale - out ", "eventText ": "cpuUtil: 1,iocapacityutil: 0,memoryUtil: 11,miscloadFactor: 1,sng - id: 0,capacity: 0.0,vcpu: 8,vnics: 10,vsns: 2,status: SUCCESS " }, "event_time ": "2015 - 03 - 10 T13: 25: 32.493000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": " / versa - nms: nms / provider / appliances / appliance[name = '10March']" }
Task Execution Complete
Routing Key
Indeterminate.versa-evt:task-execution-complete.537.System.System
AMQP Notification
{ "message_id": 34367, "event_type": "versa-evt:task-execution-complete", "event_entity": "537", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:task-execution-complete", "eventText": "task-execution-complete Upgrade Appliance: Controller-2; Upgrade Appliance: Controller-2, Status=Success" }, "event_time": "2018-10-15T07:37:59.578000+00:00", "managed_object": "537-task-execution-complete" }
Routing Key
Indeterminate.versa-evt:task-execution-complete.538.System.System
AMQP Notification
{ "message_id": 34373, "event_type": "versa-evt:task-execution-complete", "event_entity": "538", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:task-execution-complete", "eventText": "task-execution-complete Upload package FlexVNF-16.1R2-S5.1-13-10-18 to appliance: Branch-Suraj-1; Upload package FlexVNF-16.1R2-S5.1-13-10-18 to appliance: Branch-Suraj-1, Status=Success" }, "event_time": "2018-10-15T07:41:43.502000+00:00", "managed_object": "538-task-execution-complete" }
Versa Director Failover Auto
This alarm is triggered when the Versa Director performs an automatic failover and the active HA is not reachable. This alarm is generated by the active HA node. When the backup HA sends a failover started message, the backup HA node changes its state to active HA and sends a failover success message.
Routing Key
Indeterminate.versa-director-evt:ha-auto-failover.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 8, "event_type ": "versa - director - evt: ha - auto - failover ", "event_entity ": "VOAEDEVHA1 ", "severity ": "Indeterminate ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: ha - auto - failover ", "eventText ": "status: STARTED, triggered_by: system, " }, "event_time ": "2015 - 03 - 07 T06: 59: 05.697000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": "VOAEDEVHA1 - ha: auto - failover " }
Routing Key
Indeterminate.versa-director-evt:ha-auto-failover.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id ": 8, "event_type ": "versa - director - evt: ha - auto - failover ", "event_entity ": "VOAEDEVHA1 ", "severity ": "Indeterminate ", "organization ": "System ", "user ": "System ", "payload ": { "alarm - type ": "versa - director - evt: ha - auto - failover ", "eventText ": "slave: 10.192 .27 .27,status: SUCCESS,master: 10.192 .27 .26,triggered_by: system ," }, "event_time ": "2015 - 03 - 07 T07: 03: 36.321000 + 00: 00 ", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object ": "VOAEDEVHA1 - ha: auto - failover " }
Versa Director Failover Manual
This alarm is triggered when you perform a Versa Director failover manually. This alarm is generated by the active HA node. When the active HA sends a failover started message, the active HA node changes its state to backup HA and sends a failover success message.\
Routing Key
Indeterminate.versa-director-evt:ha-manual-failover.VOAEDEVHA2.System.System
AMQP Notification
{ "message_id": 6, "event_type": "versa-director-evt:ha-manual-failover", "event_entity": "VOAEDEVHA2", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-manual-failover", "eventText": "status:STARTED,triggered_by:Administrator," }, "event_time": "2015-03-07T06:55:15.231000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA2-ha:manual-failover" }
Routing Key
Indeterminate.versa-director-evt:ha-manual-failover.VOAEDEVHA2.System.System
AMQP Notification
{ "message_id": 6, "event_type": "versa-director-evt:ha-manual-failover", "event_entity": "VOAEDEVHA2", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-manual-failover", "eventText": "slave:10.192.27.26,status:SUCCESS,master:10.192.27.27,triggered_by:Administrator," }, "event_time": "2015-03-07T06:55:16.203000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA2-ha:manual-failover" }
Versa Director HA Master Arrived
This alarm is triggered when the designated active node becomes reachable. This alarm is generated by the active HA node.
Routing Key
Cleared.versa-director-evt:ha-master-arrived.ranga-dev2.System.System
AMQP Notification
{ "message_id": 110, "event_type": "versa-director-evt:ha-master-arrived", "event_entity": "ranga-dev2", "severity": "Cleared", "organization": "System", "user": "System", "payload": { "appliance-name": "ranga-dev2", "alarm-type": "versa-director-evt:ha-master-arrived", "isCleared": "true", "eventText": "Master Arrived : Master 10.192.60.11" }, "event_time": "2016-09-26T09:07:06.357000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "/versa-nms:nms/provider/appliances/appliance[name='ranga-dev2']" }
Versa Director HA Master Dead
This alarm is triggered when an active HA node is not reachable. This alarm is generated by the backup HA node.
Routing Key
Warning.versa-director-evt:ha-slave-died.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 4, "event_type": "versa-director-evt:ha-master-died", "event_entity": "VOAEDEVHA1", "severity": "Warning", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-slave-died", "eventText": "master:10.192.27.26,triggered_by:system," }, "event_time": "2015-03-07T06:59:05.399+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:master-died" }
Versa Director HA Slave Arrived
This alarm is triggered when a backup HA node transitions from an unreachable to a reachable state. This alarm is generated by the active HA node.
Routing Key
Indeterminate.versa-director-evt:ha-slave-arrived.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 2, "event_type": "versa-director-evt:ha-slave-arrived", "event_entity": "VOAEDEVHA1", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-slave-arrived", "eventText": "slave:10.192.27.27,triggered_by:system," }, "event_time": "2015-03-07T06:52:23.048000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:slave-arrived" }
Versa Director HA Slave Dead
This alarm is triggered when a backup HA node is not reachable. This alarm is generated by the active HA node.
Routing Key
Warning.versa-director-evt:ha-slave-died.VOAEDEVHA1.System.System
AMQP Notification
{ "message_id": 4, "event_type": "versa-director-evt:ha-slave-died", "event_entity": "VOAEDEVHA1", "severity": "Warning", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:ha-slave-died", "eventText": "slave:10.192.27.27,triggered_by:system," }, "event_time": "2015-03-07T06:55:14.929000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VOAEDEVHA1-ha:slave-died" }
Versa Director License Expiration
This alarm is generated if the Versa Director license will expire in less than 30 days. If the license will expire in less than 7 days, this alarm is generated every 6 hours.
Routing Key
Warning.versa-director-evt:license-validity.VersaDirector.System.System
AMQP Notification
{ "message_id": 32, "event_type": "versa-director-evt:license-validity", "event_entity": "VersaDirector", "severity": "Warning", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-director-evt:license-validity", "eventText": "Versa Director License expires in 29 days" }, "event_time": "2016-04-06T12:28:17.023000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "VersaDirector-license-validity" }
ZTP Branch Connected
Routing Key
Indeterminate.versa-evt:ztp_branch_connected.ac82c9a0-6572-4d22-8645-c95b76151030.System.System
AMQP Notification
{ "message_id": 15563, "event_type": "versa-evt:ztp_branch_connected", "event_entity": "ac82c9a0-6572-4d22-8645-c95b76151030", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:ztp_branch_connected", "eventText": "ztp_branch_connected Branch Branch-AMQP connected to Versa Director successfully after applying post-staging template" }, "event_time": "2018-06-08T09:37:50.460000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "Branch-AMQP-ztp_branch_connected" }
ZTP Cannot Start
For Release 20.2 and later.
This message is generated when there is a hardware serial number mismatch.
Routing Key
Indeterminate.versa-evt:ztp-cannot-start.Device1.System.System
AMQP Message
{ "messageId":119, "severity":"Indeterminate", "eventType":"versa-evt:ztp-cannot-start", "eventEntity":"Device1", "organization":"System", "user":"System", "subTypes":[" "], "subtype":null, "taskid":null, "payload": { "serialNum":"12345678", "appliance-name":"Device1", "eventText":"ztp-cannot-start ZTP Cannot Start on Appliance: Device1", "uuid":"5c7c084b-6acb-4f6e-808f-ee05c8ad7b98" }, "eventTime":"2019-08-19T22:06:16.069000+00:00", "eventSource":null, "eventCategory":null, "resourceType":null, "resourceUUID":null, "description":null, "directorHostname":"dir-master", "directorMgmtIP":"10.40.72.115", "managedObject":"Device1-ztp-cannot-start", "rootCauseObjects":null, "subTypePrefix":[" "] }
ZTP Device Registration
For Releases 20.2 and later.
Routing Key
Indeterminate.versa-evt:ztp-device-registration.DeviceNZTP.System.System
AMQP Message
{ "messageId":126, "severity":"Indeterminate","eventType":"versa-evt:ztp-device-registration", "eventEntity":"DeviceNZTP", "organization":"System", "user":"System", "subTypes":[" "], "subtype":null, "taskid":null, "payload": { "serialNum":"d023e7cc-73bc-4e4f-b1c8-85a6a69c97ab", "eventText":"ztp-device-registration Device registration details: deviceName=DeviceNZTP, serialNumber=d023e7cc-73bc-4e4f-b1c8-85a6a69c97ab, siteName=DeviceNZTP, regToken=B5RELoOVsKk-6OgMMPC90yHV1eY65ipGCpObQGkQ7TqXsKpw0BfTe0w_-CttK1_3jkpNHD31QTKF\n sjmx9E0xtvNlpoH5xAnTd3HVINg5iWWxcbUx7oz-tFJTwz3iayy_Blupxx3dBwQpVoPSJJ40V8Sc\n Z0ra1-IyXGiXL3GxYUdqJa3IRgaxfdL_v0fFiAGv0YjNBWlL6q8_pXA2QnoYrpC5E-6O4EA8TDix\n sUbFExHNKUpXH9zD-f9yXFbq3Joi\n" }, "eventTime":"2019-08-19T22:31:31.068000+00:00", "eventSource":null, "eventCategory":null, "resourceType":null, "resourceUUID":null, "description":null,"directorHostname":"dir-master", "directorMgmtIP":"10.40.72.115", "managedObject":"DeviceNZTP-ztp-device-registration", "rootCauseObjects":null,"subTypePrefix":[" "] }
ZTP Failure
Routing Key
Indeterminate.versa-evt:ztp_failed.Branch-4.System.System
AMQP Notification
{ "message_id": 15837, "event_type": "versa-evt:ztp_failed", "event_entity": "Branch-4", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "alarm-type": "versa-evt:ztp_failed", "eventText": "ztp_failed ZTP Failed for branch { Branch-4 }{5000=RPC error towards Branch-4: unknown_namespace: /rpc/edit-config/config}", "serialNum": "Sr004" }, "event_time": "2018-06-08T14:22:41.702000+00:00", "director_hostname":"versa-director-master", "director_mgmt_ip":"10.192.111.51", "managed_object": "Branch-4-ztp_failed" }
ZTP Poststaging Failed
Routing Key
Indeterminate.versa-evt:ztp_poststaging_failed.Branch-Pepsi.System.System
AMQP Notification
{ "message_id": 3673, "event_type": "versa-evt:ztp_poststaging_failed", "event_entity": "Branch-Pepsi", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "appliance-name": "Branch-Pepsi", "eventText": "ztp_poststaging_failed ZTP Failed at poststaging for branch { Branch-Pepsi }{5000= Configuration template not assosiated with the device }", "uuid": "187efa53-adf9-467a-8c8f-5fe6dc971557", "serialNum": "SR101" }, "event_time": "2019-01-28T18:00:20.185000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "Branch-Pepsi-ztp_poststaging_failed" }
ZTP Poststaging Start
Routing Key
Indeterminate.versa-evt:ztp_poststaging_start.Branch-Versa-PreStage.System.System
AMQP Notification
{ "message_id": 3837, "event_type": "versa-evt:ztp_poststaging_start", "event_entity": "Branch-Versa-PreStage", "severity": "Indeterminate", "organization": "System", "user": "System", "payload": { "eventText": "ztp_poststaging_start ZTP started poststaging to apply staging template Versa on Branch-Versa-PreStage serialNumber: SR117", "serialNum": "SR117" }, "event_time": "2019-01-28T18:34:35.182000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "Branch-Versa-PreStage-ztp_poststaging_start" }
ZTP Staging Failed
Routing Key
Indeterminate.versa-evt:ztp_staging_failed.Branch-Versa-PreStage.Versa.System
AMQP Notification
{ "message_id": 4004, "event_type": "versa-evt:ztp_staging_failed", "event_entity": "Branch-Versa-PreStage", "severity": "Indeterminate", "organization": "Versa", "user": "System", "payload": { "appliance-name": "Branch-Versa-PreStage", "eventText": "ztp_staging_failed ZTP Failed at staging for branch { Branch-Versa-PreStage }{5000=Connection to Branch-Versa-PreStage timed out}", "uuid": "c10f365d-3d47-4e11-9c38-2736cd8896b2", "serialNum": "SR117" }, "event_time": "2019-01-29T11:37:52.383000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "Branch-Versa-PreStage-ztp_staging_failed" }
ZTP Staging Start
Routing Key
Indeterminate.versa-evt:ztp_staging_start.Branch-Versa-PreStage.Versa.System
AMQP Notification
{ "message_id": 3959, "event_type": "versa-evt:ztp_staging_start", "event_entity": "Branch-Versa-PreStage", "severity": "Indeterminate", "organization": "Versa", "user": "System", "payload": { "appliance-name": "Branch-Versa-PreStage", "eventText": "ztp_staging_start ZTP started staging to apply staging template Template-Prestaging on Branch-Versa-PreStage serialNumber: SR117", "uuid": "db185cc0-b70b-47ea-b3e3-3b1ffb5a20e5", "serialNum": "SR117" }, "event_time": "2019-01-29T10:59:37.394000+00:00", "director_hostname": "versa-director-master", "director_mgmt_ip": "10.192.111.51", "managed_object": "Branch-Versa-PreStage-ztp_staging_start" }
Supported Software Information