This article describes the front and rear panel components of a Cloud Services Gateway (CSG) 620h series appliance. For the exact location of these components on the appliance, see At a Glance.

Front Panel

The front panel of a CSG620h series appliance includes status LEDs, the power button, and various connectors and ports, as shown in Figure 1.

Figure 1: Front Panel of a CSG620h Series Appliance

620h_front.png

LEDs

Table 1 lists the LEDs, their colors and states, and the status they indicate.

Table 1: Front Panel LEDs in a CSG620h Series Appliance

LED Color Status
Power Green
  • Off—Appliance is not powered on.
  • Green—Appliance is powered on
Status Green, Red
  • Off—Appliance hardware is up, but there is a problem with the configuration or software.
  • Solid green—Controller connection is up and running, and probes and control plane packets are being transmitted.
  • Blinking green—Controller connection is in the process of being established.
  • Solid red—Controller or CA has rejected this appliance, there is a certificate mismatch, or the appliance is unreachable.
  • Blinking red—Controller is unreachable or unresponsive.
Cloud Green, Red Currently not supported.

Power Button

The power button on the front panel of a CSG620h series appliance turns the power on and off.

To turn the power on, press and immediately release the power button when the appliance is off.

To turn the power off, press the power button when the appliance is on, as follows:

  • If you press and immediately release the button, the appliance does a graceful software shutdown that is equivalent to issuing the shutdown now command from the operating system shell.
  • If you press and hold the button for 10 seconds or more, the power for the appliance turns off and the appliance shuts down.

Rear Panel

The rear panel of a CSG620h series appliance has the power connector and the reset button, as shown in Figure 2:

Figure 2: Rear Panel of a CSG620h Series Appliance

620h_back.png

Reset Button

The reset button on the front panel of a CSG620h series appliance resets the appliance. The reset functionality depends on the number of times you press the button within a span of 30 seconds, as described in Table 2. In between each press on the reset button, you must pause for a second to register the key presses.

The reset button is recessed so that it is not accidentally pressed while the appliance is operational.

To press the reset button, use a sharp, narrow tool.

Table 2: Reset Button Press Behavior

Number of Presses Behavior
2 Reset the appliance to the factory-default snapshot.
4 Reset the appliance to the branch prestaging configuration.
6 Reset the appliance to the branch staging configuration.
8 Reset the appliance to branch post-staging configuration.

You can reset the appliance to the factory-default configuration by issuing the request system reset CLI command.

Reset the Appliance to the Factory-Default Configuration from the CLI 

You can reset the appliance to the factory-default configuration from the CLI. You can connect to the appliance through the serial console port or by using SSH.

The factory default reset procedure may take up to 20 minutes to complete. Do not power off the appliance during this time.

To reset an appliance to the factory default configuration:

  1. To connect to the appliance through the serial console port, see Configure a Management Console to Connect to a CSG620h Series Appliance.
  2. Log in to the appliance CLI. Please consult Versa Networks technical support for default credentials.

Note: To connect to the appliance using SSH, connect your PC to the management port of the appliance. For the port mapping on the CSG620h series appliance, see Interface Numbering. The management port has the default static IP address 10.10.10.10/24. Configure the PC IP address to any IP from this segment, for example, 10.10.10.1/24. Open an SSH session to the appliance using its IP address, 10.10.10.10.

  1. Start the CLI:
     
    $ cli
  2. Enter the configure command to switch to configuration mode. The prompt changes to %. 
  3. Issue the request system reset command to reset the configuration to the factory default. If the current software version on the appliance is the same as that of the factory reset snapshot, the procedure takes about 10 minutes to complete. If the software versions are different, the procedure takes about 20 minutes to complete. Do not power off the appliance during the process.
    % request system reset
  4. Verify that all Versa services are running by issuing the vsh status command from the Linux shell. The following is a sample output of this command. If all the services are shown as stopped, issue the vsh start command from the Linux shell to start them manually.
    # vsh status
    versa-service    is Running, [*] process 6784
    versa-infmgr     is Running, [-] process 5623
    versa-rfd        is Running, [-] process 5838
    versa-vmod       is Running, [-] process 5839
    versa-ip2user    is Running, [-] process 5844
    versa-imgr       is Running, [-] process 5848
    versa-acctmgrd   is Running, [-] process 5845
    versa-fltrmgr    is Running, [-] process 5648
    versa-vstated    is Running, [-] process 5625
    versa-addrmgrd   is Running, [-] process 5857
    versa-rt-cli-xfm is Running, [-] process 5798
    versa-rtd        is Running, [-] process 5827
    versa-dhcpd      is Running, [-] process 5620
    versa-eventd     is Running, [-] process 5843
    versa-vrrpd      is Running, [-] process 5643
    versa-dnsd       is Running, [-] process 5646
    versa-ppmd       is Running, [-] process 5793
    versa-snmp-xform is Running, [-] process 5800
    versa-certd      is Running, [-] process 5849
    versa-ntpd       is Running, [*] process 5612
    versa-dhclient6  is Running, [-] process 5807
    versa-redis      is Running, [-] process 6927
    versa-av-redis   is Running, [-] process 5003
    versa-spackmgr   is Running, [-] process 5832
    versa-monit      is Running, [*] process 6078
    versa-confd      is Running, [*] process 4798
    versa-fail2ban   is Running, [*] process 6093
    versa-auditd     is Running, [*] process 6116
    versa-nodejs     is Running, [-] process 5775 
  5. Power off the appliance.