Skip to main content
Versa Networks

Validated SFPs for CSG5000 Series Appliances

This article lists the small form-factor pluggable (SFP/SFP+) optics supported on the Cloud Services Gateway (CSG) 5000 series appliance fiber interfaces, and it describes the remote switches that have been tested with the SFPs.

Supported VNI and Ethernet Ports

You can install SFP, SFP+ ,SFP28, and QSFP28 transceivers in the following ports:

  • Virtual network interface (VNI) ports vni-0/0 through vni-0/3
  • Ethernet ports enet-0/4 through enet-0/36

The VNI and Ethernet ports on the CSG5200 and CSG5250 appliances use different Ethernet controllers and support different SFPs.

The following table describes the VNI ports, controllers, and supported transceivers on the CSG5000 series appliances.

Appliance Ports Supported SFP/SFP+/QSFP
CSG5000 vni-0/0 through vni-0/15 1/10/25-Gigabit Ethernet fiber ports
vni-0/16 through vni-0/19 100-Gigabit Ethernet fiber ports
Direct attach copper cable (copper DAC)
CSG5200 vni-0/0 through vni-0/15 10/25-Gigabit Ethernet SFP fiber ports
vni-0/16 through vni-0/19 100-Gigabit Ethernet QSFP fiber ports
CSG5250 vni-0/0 through vni-0/7 10/25-Gigabit Ethernet SFP fiber ports
vni-0/8, vni-0/12, and vni-0/16 through vni-0/19 100-Gigabit Ethernet QSFP fiber ports

Supported 1-Gigabit Ethernet SFP Transceivers

The following table  describes the 1-Gigabit Ethernet SFP transceiver modules supported on the CSG5000, CSG5200, and CSG5250 model appliances.

Type Manufacturer Part Number

Supported Ports

(CSG5000 and CSG5200)

Supported Ports

(CSG5250)

Transceiver Description
Short wavelength (SX) Finisar FTLF8519P3BNL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7 1000BASE-SX Ethernet 500-m extended temperature SFP optical transceiver
Long wavelength (LX) Finisar FTLF1318P3BTL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7 1000BASE-LX Ethernet 10-km industrial temperature Gen 3 SFP optical transceiver

Supported 10-Gigabit Ethernet SFP+ Transceivers

The following table describes the 10-Gigabit Ethernet SFP+ transceiver modules supported on the CSG5000, CSG5200, and CSG5250 model appliances.

Type Manufacturer Part Number

Supported Ports

(CSG5000 and CSG5200)

Supported Ports

(CSG5250)

Transceiver Description
Short-reach (SR) Finisar FTLX8574D3BCL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7

10GBASE-SR/SW 400-m multimode datacom SFP+ optical transceiver

Long-reach (LR) Finisar FTLX1475D3BCL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7 10GBASE-LR/LW 10-km 1310-nm single mode datacom SFP+ optical transceiver

Supported 25-Gigabit Ethernet SFP28 Transceivers

The following table describes the 25-Gigabit Ethernet SFP28 transceiver modules supported on the CSG5000, CSG5200, and CSG5250 model appliances.

Type Manufacturer Part Number

Supported Ports

(CSG5000 and CSG5200)

Supported Ports

(CSG5250)

Transceiver Description
Short-reach (SR) Finisar FTLF8536P5BCL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7 25-Gigabit Ethernet-SR SFP28 300-m multimode optical transceiver
Long-reach (LR) Finisar FTLF1436P3BCL vni-0/0 through vni-0/15 vni-0/0 through vni-0/7 25-Gigabit Ethernet 1310-nm SFP28 10-km single mode optical transceiver

Supported 100-Gigabit Ethernet QSFP28 Transceivers and Cables

The following table describes the 100-Gigabit Ethernet QSFP28 transceiver modules supported on the CSG5000, CSG5200, and CSG5250 model appliances.

Type Manufacturer Part Number

Supported Ports

(CSG5000 and CSG5200)

Supported Ports

(CSG5250)

Transceiver Description
Short-reach (SR) Finisar FTLC9558REPM/ FTLC9555REPM vni-0/0 through vni-0/15 vni-0/8, vni-0/12, and vni-0/16 through vni-0/19 100-m parallel MMF 100-GB QSFP28 multimode optical transceiver
Long-reach (LR) Finisar FTLC1154RDPL/ FTLC1156RDPL vni-0/0 through vni-0/15 vni-0/8, vni-0/12, and vni-0/16 through vni-0/19 10-km 1310-nm 100-GB QSFP28 single-mode optical transceiver
Direct attach copper cable (DAC) FS QSFP-100G vni-0/0 through vni-0/15 vni-0/8, vni-0/12, and vni-0/16 through vni-0/19 QSFP-100G-CU5M–compatible 100-GB QSFP28 passive direct-attach copper cable

Compatible Remote Switches

The following switches have been tested with a 1-Gigabit Ethernet link connection to the CSG5000 series appliances:

  • Cisco Nexus-3048T
  • Dell S3048 and S4128F switches
  • Juniper EX2200

Connection Recommendations

The following are recommendations for connecting the CSG5000 series appliance at 10/25/100-Gigabit Ethernet speeds:

  • After you insert an SFP or change the SFP speed, you must disable and then re-enable the VNI interface on the CSG5000 series appliance.
  • If the configuration on the remote device changes, you must disable and then reenable the VNI interface on the CSG5000 series appliance.
  • Ensure that you have enabled the 1-Gigabit Ethernet interface in the Versa Operating SystemTM (VOSTM) software.
  • For 1-Gigabit Ethernet SFPs, you must turn off autonegotiation on the remote device, and then you must set the connection speed to 1-Gigabit Ethernet. For example, for Cisco switches, in the interface configuration, configure the speed to 1000:
interface Ethernet 1/25 
speed 1000

For Juniper switches, configure no-autonegotiation on the interface:

enable;
ether-options {
    no-auto-negotiation;
    link-mode full-duplex;
    speed {
        1g;
     }
}

Note: Before you order units in bulk, validate connections with the target remote device in a lab or testing environment to ensure that there are no compatibility or link issues.

  • Was this article helpful?